Self-healing Behaviour as a Quality Standard
The capacitors
manufactured by WIMA in winding technology are produced as
single winding capacitors. The most effective pressure on the
layers necessary for good self-healing
behaviour can be individually adjusted for each
capacitor.
WIMA capacitors are
known for their excellent self-healing behaviour.
A DC voltage test is
used to demonstrate the self-healing properties:
- the capacitor to be
tested is connected over a series resistance of R ~
10 k
at with adjustable direct voltage source.
- the voltage on the
capacitor is observed with a line recorder or an
oscilloscope (see diagram).

- the voltage applied to the capacitor is
continually increased, over and above the rated voltage for
the capacitor, up to the first self-healing process. The
line recorder shows clear breakdowns in the capacitor
voltage and then recharging until the next self-healing
occurs.
The voltage rate at the
first breakdown and the number of self-healings which happen
before the short-circuit finally occurs, allow definite
conclusions to be drawn about the capacitor dimensioning or
type. This clearly shows that stacked MKT film capacitors
short-circuit after a few self-healing processes. Also, the
rate of the breakdown voltage is usually distinctly lower. A
low loading capacity and a reduced life time are the
result.
WIMA capacitors, on the
other hand, are surprisingly hardy. As well as having very
high breakdown voltage, they self-heal much more frequently
than corresponding stacked film capacitors. The test clearly
proves the high reliability and long life-span of WIMA MKS
capacitors, well above the data given in the
catalogue. |
|
|