The values of the WIMA FKS 02 and WIMA FKM 02 ranges according to the main catalogue 2009 are still available on request.
Polypropylene (PP) Film and Foil Capacitors
for Pulse Applications in PCM 2.5 mm
Special
Features
Pulse
duty construction
PCM 2.5 mm
Close tolerances up to ±2.5%
Very low dissipation factor
Negative capacitance change versus
temperature
Very low dielectric absorption
According to RoHS 2011/65/EU
Typical
Applications
For high
frequency applications e.g.
Sample and hold
Timing
LC-Filtering
Oscillating circuits
Audio equipment
Construction
Dielectric:
Polypropylene (PP) film. Capacitor electrodes: Metal foil Internal construction:
Encapsulation:
Solvent-resistant, flame-retardent plastic case
with epoxy resin seal, UL 94 V-0. Terminations:
Tinned wire Marking:
Colour: Red. Marking: Black. Epoxy resin seal:
Yellow.
Electrical Data
Capacitance
range: 100 pF to 0.01 µF
(E12-values on request)
Rated voltages: 63VDC, 100VDC, 250VDC, 400VDC
Capacitance tolerances: ±20%, ±10%, ±5%, ±2.5%
Operating temperature range: -55°C to +100°C Test specifications:
In accordance with IEC 60384-13 Climatic test category:
55/100/21 in accordance with IEC Insulation resistance at +20°C: > 5 x 105 M (mean value: 1 x 106 M)
Measuring voltage:
Ur = 63V: Utest = 50 V/1 min.
Ur > 100V: Utest = 100 V/1 min. Test voltage: 2 Ur, 2 sec Maximum pulse rise time:
1000 V/µsec for pulses equal to the rated
voltage.
Dielectric absorption: 0.05%
Temperature coefficient: -200 x 10-6/°C (typical) Dissipationfactors at +20°C:
tan
at f
C < 0.01 µF
1kHz
10kHz
100kHz
< 4 x 10-4 < 4 x 10-4 < 6 x 10-4
Voltage derating:
A voltage derating factor of 1.35% per K
must be applied from +85°C for DC
voltages and from +75°C for AC voltages. Reliability: Operational life > 300000
hours
Failure rate < 5 fit (0.5 x Ur and
40°C) Graphs:
Pull test on pins: 10 N in direction of pins according to
IEC 60068-2-21 Vibration:
6 hours at 10...2000Hz and 0.75mm displacement
amplitude or 10g in accordance with IEC 60068-2-6 Low air density:
1kPa = 10 mbar in accordance with IEC 60068-2-13 Bump test:
4000 bumps at 390 m/sec2 in accordance
with IEC 60068-2-29