Capacitance range:
0.01 µF to 6.8 µF Rated voltages:
63VDC, 100VDC, 250VDC, 400VDC, 630VDC, 1000VDC Capacitance tolerances:
±20%, ±10%, (±5% available subject to special enquiry). Operating temperature range:
-55°C to +100°C (+125°C available subject to special enquiry) Climatic test category:
55/100/21 according to IEC for size codes 1812 to 2824
55/100/56 according to IEC for size codes 4030 to 6054 Test voltage:
1.6 Ur, 2 sec Insulation resistance at +20°C:
Voltage derating:
A voltage derating factor of 1.25% per K must be
applied from +85°C for DC voltages and from
+75°C for AC voltages. Reliability: Operational life > 300000 hours
Failure rate < 2 fit (0.5 x Ur and 40°C)
Resistance to soldering
heat: Test Tb in accordance with DIN IEC
60068-2-580/DIN EN 60384-19.
Soldering bath temperature
max. 260°C.
Soldering duration max. 5sec.
Change in capacitance C/C<5%.
Soldering process:
Re-flow soldering.